Meet the C&D Emerging Energy’s reliable mobile power solution. It is compatible with both traditional and smart generators, safeguarding the batteries of your vehicle while reaching up to 95% charging efficiency. With advanced charging logic, the charger improves performance for better energy management. From RVs to off-grid applications, this charger delivers the smart, stable energy you need — wherever you go.
Not used "IGNTION” --Do not connect the ACC
CH3: Start Battery Original vehicle battery input channel
Charging logic
>12.5V charging starts after 5s≤12.3V±0.1V stop charging
>25V charging staris aiter 5s≤24.6V±0.2V stop charging
Voltage range
12.5-16Vdc
25-32Vdc
Voltage system identification
<17Vdc
>17Vdc
Normal starting voltage
>13.2Vdc
>26.4Vdc
Overvoltage proteciion point
>16.5V
>32.5V
Overvoltage recovery point
<16V
<32V
Undervoltage protection point
<12.3Vdc
<24.6Vdc
Undervoltage recovery point
>12.5Vdc
>25Vdc
CH2:Solar ArayPV inputchannel
Voltage range
14.5-45Vdc
Undervoltage protection point
<14.1Vdc
Undervoltage recovery point
>14.5Adc
Overvoltage protection point
>46V
Overvoltage recovery point
<45V
MAX power
<23V input.500W(MAX600W);≥37.5-45V input,750W(MAX 800W)
CH1:House Battery House Battery Channel
Battery type
AGM/GEL/FLOODED/LITHIUM
Output voltage
13.8-15.5Vdc, Typical value: 12v, Min: 8v
Overvoltage protection
16Vdc
Overvoltage recovery
15.5Vdc
Output current
5/10/15/20/25130135/40/45/50A
Output power
775W
Leakage current
<50mA
Efficiency
95%
BTS
Temperature detection
Operating temperature descriptionNo lithium battery, set to nor and disconnect the sensor
Remote
Long-range
CAN
Use "IGNITION"--connect the ACC
CH3:Start BatteryOriginal vehicle battery input channel
Parameter
12V
24V
Normal starting voltage
>12V
>24V
Charging logic
>12.5V charging starts after 5s≤11.8V±0.1V stop charging
>24V charging starts after 5s≤23.6V±0.2V stop charging
WEITERLESEN